How to Protect the Oxygen Analyzer Toray from Getting Damaged?

How to Protect the Oxygen Analyzer Toray from Getting Damaged

Oxygen in the products can lead to damage to them. Thus, it is very important for you to detect the oxygen concentration in the materials like food packages or medicines to protect them from getting destroyed. The LC-450F zirconia oxygen analyzer is one of the accurate testing instruments that will help you to analyze the oxygen levels of different sorts of materials and help you to keep up with the food quality. Thus, you can easily test the concentration of oxygen food packages, beverages, or medicines with the help of this amazing lab testing equipment from Toray.

This testing instrument comes with a solid battery system that can easily measure the package at high precision. Thus, you can easily conduct the test using an oxygen analyzer-Toray for sampling inspection after gas filling using a pen-shaped probe.

Here, we are going to discuss how you can easily protect the oxygen analyzer-Toray from getting damaged. But before that, we will discuss how this lab testing equipment serves to be useful in determining the oxygen levels of the product.

How is the oxygen analyzer –Toray used to determine the quality of the product?

This high-quality zirconia oxygen analyzer is one of the high-quality testing equipment that will be used to test the oxygen level present in different products like food packages, medicinal products, etc. Thus, with the help of this amazing lab testing instrument, you can analyze the oxygen easily and accurately. Whenever you conduct the test using an o2 analyzer from Toray, then you need to follow some precautions for setting it. Thus, you can ensure that the best product will be delivered to your customers.

To conduct the test accurately using this lab testing equipment, you need to place the specimen accurately with the help of this lab testing machine. You can follow the below-mentioned steps:

  1. Start by simply connecting the sampling probe and foot switch/measurement switch to the machine.
  2. Once you select the needle for testing, you can easily attach it with the sampling probe.
  3. Press CAL for 3 seconds then CAL A will appear on the display.
  4. Wait for approx. three to four minutes for warm-up.
  5. Press CAL for 3 seconds more and go back to the measurement display.
  6. Insert the needle attached to the rubber sheet and press measurement/footswitch for measuring oxygen percentage.
  7. You can easily display the oxygen percentage in the sample.

In this way, you can easily test the specimen accurately with the help of this lab testing equipment. Whenever you conduct the test with the help of Zirconia Oxygen Analyzer then you need to keep some factors in mind. You can read about the top 4 factors to be considered before using an oxygen analyzer.

Here we have created a list of its features and technical specifications.

Features of oxygen analyzer Toray

This amazing lab testing equipment has been used has been equipped with an advanced set of features. We have listed them below.

  • Easy to operate and accurately measure the oxygen.
  • Made with solid-state manufacturing technique.
  • It has been compliant with the RoHS directive and is more environment-friendly.
  • It comes with an environment-conscious design.
  • You will get notified of the test completion.
  • The necessary sampling amount for measurement is very small.

These are the features you will get with the use of this lab testing instrument. You can read about oxygen analyzer top features below.

Technical Specifications of Toray oxygen analyzer

  • Communication method: Single-way transmission
  • Interface: Conformed to RS-232C standard
  • Synchronization method : Start-stop synchronization
  • Character configuration: 10 bits
  • Baud Rate: Selection among 19200/9600/4800 bps. The standard product is shipped in 9600 bps setting
  • Communication cable: RS232C cross (reverse) cable
  • Control code: ASCII code (JIS 7-bit code compatible with alphabetic letters)

These are the technical specifications you will get with the Toray oxygen analyzer. Now, let us focus on the tips to maintain your product and avoid any damage.

Tips to protect the oxygen analyzer-Toray for longer use

There are certain tips that will help you to use the oxygen analyzer- Toray from getting damaged. Thus you can easily follow these tips to get an accurate measurement of results.

  • Whenever you conduct the test using an oxygen analyzer, then you must keep it safe from water. You should not drop the water in the sample as it may cause measurement errors.
  • In order to maintain the performance of the oxygen analyzer and prevent malfunctions, check it regularly and calibrate it with standard gas.
  • Before turning off the power of the oxygen analyzer at stopping the equipment, make sure that the measured gas does not remain in the sensor section by flowing sufficient clean air or inert gas in advance.
  • Keep the measured gas temperature below 50? while taking measurements.
  • Remove combustible gases (CO, H2, etc.) and oil vapors.

These are some useful tips you can opt for using an oxygen analyzer-Toray. You should make sure that the instrument should be kept clean and free of any damage. Thus, you can read about the steps for cleaning the oxygen analyzer Toray. If you need any help regarding the use of this testing instrument, then give us a call at +91 9210903903 or email us at info@prestogroup.com. Our technical experts will guide you well regarding your queries.